Urine Specific Gravity (SG) screening is a quick, non-invasive monitoring tool used to assess the urine concentration, especially in patients at risk of:


Specific Gravity (SG) Interpretation
>1.020 g/mL Concentrated urine (normal in dehydration, SIADH)
1.005–1.020 g/mL Normal range (depending on hydration)
<1.005 g/mL Hypotonic urine β†’ may indicate AVP deficiency

* After transsphenoidal surgery, hypotonic urine with rising serum sodium is a red flag for developing diabetes insipidus (DI). * Monitoring SG helps detect water diuresis early and avoid dangerous hypernatremia.


Method Tool Notes
Test strips e.g., Combur-10 Easy, fast, semi-quantitative
Refractometer ATAGO MASTER-SUR/NΞ± or similar More precise but requires staff

According to a 2025 study of Nollen et al.

  • Patients can self-monitor urine SG using dipsticks.
  • A threshold of 1.015 g/mL ensures no hypotonic urine is missed.
  • This can reduce nurse-led testing by ~50%.

1)


Use SG <1.005 g/mL as a critical marker of AVP deficiency. For self-testing, use β‰₯1.015 g/mL as a safe threshold to rule out hypotonic urine.


Article: Patient Participation in Urine Specific Gravity Screening for Arginine Vasopressin Deficiency in an Inpatient Neurosurgical Clinic Authors: Jeanne-Marie Nollen et al. Journal: Clinical Endocrinology (Oxf), March 27, 2025 DOI: 10.1111/cen.15241 PMID: 40145244


To evaluate whether post-pituitary surgery patients can reliably screen for hypotonic urine (SG < 1.005 g/mL) using dipsticks, compared to nurse measurements using a refractometer, in the early detection of Arginine vasopressin deficiency (AVP-D).


  • Design: Prospective cohort study
  • Setting: Neurosurgical ward
  • Participants: 110 patients, 609 urine SG measurements
  • Tools:
    • Combur-10 test strips (patients)
    • ATAGO refractometer (nurses)
  • Statistical analysis: Weighted Kappa and ICC

Comparison Kappa ICC Interpretation
Patient (strip) vs Nurse (refractometer) 0.47 0.69 Moderate agreement
Patient (strip) vs Nurse (strip) 0.82 0.89 Substantial to good agreement
  • SG cut-off of 1.015 g/mL: avoided all false negatives.
  • Nurse workload: reduced by ~50%.
  • Patient satisfaction: 7.8 / 10
  • Nurse satisfaction: 6.4 / 10

  • Clinically relevant and easy to implement
  • Prospective, well-designed methodology
  • Supports task-shifting and patient empowerment
  • Proposes a safe operational cut-off for SG (β‰₯1.015)
  • Reduces unnecessary confirmatory testing in low-risk patients

  • Only moderate agreement with the gold standard
  • No data on real clinical outcomes (e.g. missed AVP-D)
  • Single-center study limits generalizability
  • Training quality for patients not specified
  • Lower nurse satisfaction may indicate workflow concerns

This study suggests that patient self-screening of urine SG using test strips is feasible and safe, particularly when using a conservative threshold (β‰₯1.015 g/mL). It is best suited as a triage tool, not a replacement for diagnostic confirmation.

When applied correctly, this approach can enhance early AVP-D detection and reduce unnecessary nurse-led testing.


  • Useful for early postoperative monitoring after pituitary surgery
  • May reduce resource strain in neurosurgical wards
  • Encourages structured patient education and autonomy

Nollen et al. propose a low-cost, patient-participatory method to monitor for AVP deficiency after neurosurgical interventions. While not without limitations, the approach is clinically valuable and aligns with modern principles of patient-centered care. Further validation and outcome-based studies are needed.


1)
Nollen JM, Brunsveld-Reinders AH, Biermasz NR, Verstegen MJT, Leijtens E, Peul WC, Steyerberg EW, van Furth WR. Patient Participation in Urine Specific Gravity Screening for Arginine Vasopressin Deficiency in an Inpatient Neurosurgical Clinic. Clin Endocrinol (Oxf). 2025 Mar 27. doi: 10.1111/cen.15241. Epub ahead of print. PMID: 40145244.