Show pageBacklinksCite current pageExport to PDFBack to top This page is read only. You can view the source, but not change it. Ask your administrator if you think this is wrong. ====== Intraoperative Computed Tomography ====== [[Computer]]-assisted [[navigation]] (CAN) may guide [[spinal instrumentation]] and requires alignment of patient [[anatomy]] to [[imaging]]. Iterative closest-point (ICP) [[algorithm]]s register anatomical and imaging surface [[dataset]]s, which may fail in the presence of geometric symmetry (congruence), leading to failed registration or inaccurate navigation. Guha et al. computationally quantified geometric congruence in posterior spinal exposures, and identify predictors of potential navigation inaccuracy. Midline posterior exposures were performed from C1-S1 in four human [[cadaver]]s. An optically-based CAN generated surface maps of the posterior elements at each level. Maps were reconstructed to include bilateral hemilamina or unilateral hemilamina with/without the base of the spinous process. Maps were fitted to symmetrical geometries (cylindrical/spherical/planar) using computational modeling, and the degree of model fit quantified based on the ratio of model inliers to total points. Geometric congruence was subsequently assessed clinically in 11 patients undergoing midline exposures in the cervical/thoracic/lumbar spine for posterior instrumented fusion. In cadaveric testing, increased cylindrical/spherical/planar symmetry was seen in the high-cervical and [[subaxial]] cervical spine relative to the thoracolumbar spine (p<0.001). Extension of unilateral exposures to include the ipsilateral base of the spinous process decreased symmetry independent of spinal level (p<0.001). In clinical testing, increased cylindrical/spherical/planar symmetry was seen in the subaxial cervical relative to the thoracolumbar spine (p<0.001), and in the thoracic relative to the lumbar spine (p<0.001). Symmetry in unilateral exposures was decreased by 20% with inclusion of the ipsilateral base of the [[spinous process]]. Geometric congruence is most evident at [[C1]] and the subaxial cervical spine, warranting greater vigilance in navigation accuracy verification. At all levels, the inclusion of the base of the spinous process in unilateral registration decreases the likelihood of geometric symmetry and navigation error. This work is important to allow the extension of line-of-sight based registration techniques to minimally-invasive unilateral approaches ((Guha D, Jakubovic R, Leung MK, Ginsberg HJ, Fehlings MG, Mainprize TG, Yee A, Yang VXD. Quantification of computational geometric congruence in surface-based registration for spinal intra-operative three-dimensional navigation. PLoS One. 2019 Aug 26;14(8):e0207137. doi: 10.1371/journal.pone.0207137. eCollection 2019. PubMed PMID: 31450234. )). ---- CT-guided navigation allows for 3-dimensional visualization of the [[cervicothoracic junction]] (CTJ) and minimizes complications associated with inadequate surgical visualization of vascular and deep organ structures ((Shin JH, Yanamadala V, Cha TD. [[Computer-Assisted Navigation]] for real-time Planning of Pedicle Subtraction Osteotomy in Cervico-Thoracic Deformity Correction. Oper Neurosurg (Hagerstown). 2018 Aug 17. doi: 10.1093/ons/opy162. [Epub ahead of print] PubMed PMID: 30124922.)). Currently, intraoperative [[computed tomography]] (iCT) is a scarcely used [[technique]] in neurosurgery. It remains unclear whether this phenomenon is explained by unfavorable iCT-related workflows and/or a limited number of indications. ===== Systems ===== see [[Intraoperative Computed Tomography systems]]. ---- 18 [[patient]]s underwent [[DBS]] with bilateral implantation of [[directional electrode]]s applying a 32-slice [[portable CT]] scanner in combination with [[microelectrode recording]]. iCT led to a significant decrease in overall procedural time, despite performing multiple [[scan]]s. In three of the initial 5 cases iCT caused an adjustment of the final electrodes demonstrating the [[learning curve]] and the necessity to integrate road mapping for the exchange of [[microelectrode]] to final electrode. Implementation of low-dose CT protocols added microelectrode iCT to the refined workflow, resulting in an intraoperative adjustment of a trajectory in one patient. Low-dose protocols lowered the total effective dose to 1.15 mSv, i.e. a reduction by a factor of 3.5 compared to a standard non-iCT DBS procedure, despite repeated iCTs. Intraoperative lead detection based on final iCT revealed a radial error of 1.04 ± 0.58 mm and a vector error of 2.28 ± 0.97 mm compared to the preoperative planning, adjusted by the findings of microelectrode recording. iCT can be easily integrated into the surgical workflow resulting in an overall efficient time saving procedure. Repeated intraoperative scanning ensures reliable electrode placement, while low-dose scanning protocols prevent extensive radiation exposure. iCT of microelectrodes is feasible and led to an adjustment of one electrode ((Carl B, Bopp M, Gjorgjevski M, Oehrn C, Timmermann L, Nimsky C. Implementation of [[intraoperative computed tomography]] for [[deep brain stimulation]]: [[pitfall]]s and optimization of [[workflow]], [[accuracy]], and [[radiation exposure]]. World Neurosurg. 2018 Dec 26. pii: S1878-8750(18)32902-4. doi: 10.1016/j.wneu.2018.12.079. [Epub ahead of print] PubMed PMID: 30593970. )). ---- i-CT combined to [[awake surgery]] is reliable and effective. It does not significantly affect surgical time and it does not add stress to patient. The possibility to correct for [[brain shift]] also in awake patients can increase precision and accuracy of surgery, particularly in cases of [[Low-Grade Glioma]]s, avoiding resection of normal [[white matter]] or tumor remnants in non-eloquent areas ((Barbagallo GMV, Morrone A, Certo F. Intraoperative CT and awake craniotomy: a useful and safe combination in brain surgery. World Neurosurg. 2018 Jul 18. pii: S1878-8750(18)31556-0. doi: 10.1016/j.wneu.2018.07.078. [Epub ahead of print] PubMed PMID: 30031198. )). ---- Intraoperative [[computed tomography]] (iCT) has gained increasing impact among modern neurosurgical techniques. Multislice CT with a sliding gantry in the OR provides excellent diagnostic image quality in the visualization of vascular lesions as well as bony structures including skull base and spine. Due to short acquisition times and a high spatial and temporal resolution, various modalities such as iCT-angiography, iCT-cerebral perfusion and the integration of intraoperative navigation with automatic re-registration after scanning can be performed. This allows a variety of applications, e.g. intraoperative angiography, intraoperative cerebral perfusion studies, update of cerebral and spinal navigation, stereotactic procedures as well as resection control in tumour surgery. Its versatility promotes its use in a multidisciplinary setting. Radiation exposure is comparable to standard CT systems outside the OR. For neurosurgical purposes, however, new hardware components (e.g. a radiolucent headholder system) had to be developed. Having a different range of applications compared to intraoperative MRI, it is an attractive modality for intraoperative imaging being comparatively easy to install and cost efficient ((Tonn JC, Schichor C, Schnell O, Zausinger S, Uhl E, Morhard D, Reiser M. Intraoperative computed tomography. Acta Neurochir Suppl. 2011;109:163-7. doi: 10.1007/978-3-211-99651-5_25. PubMed PMID: 20960337. )). Intraoperative [[Computed Tomography]] is a useful tool to check the correct position of the implants used, the extent of decompression and the realignment as early as possible. It therefore reduces second operations. A postoperative CT is no longer necessary ((Steudel WI, Nabhan A, Shariat K. Intraoperative CT in spine surgery. Acta Neurochir Suppl. 2011;109:169-74. doi: 10.1007/978-3-211-99651-5_26. PubMed PMID: 20960338. )). ---- A study reports the experience of Terpolilli et al with the use of intraoperative CT (iCT) combined with [[neuronavigation]] with regard to feasibility and possible benefits of the method. Those patients with tumorous lesions in relationship to the [[orbit]], [[sphenoid wing]], or [[cavernous sinus]] who were surgically treated between October 2008 and December 2013 using iCT-based neuronavigation and in whom an intraoperative scan was obtained for control of resection were included. In all cases a second iCT scan was performed under sterile conditions after completion of navigation-guided microsurgical tumor resection. The surgical strategy was adapted accordingly; if necessary, resection was continued. Twenty-three patients (19 with WHO Grade I [[meningioma]] and 4 with other lesions) were included. The most common clinical symptoms were loss of visual acuity and [[exophthalmos]]. Intraoperative control of resection by iCT was successfully obtained in all cases. Intraoperative imaging changed the surgical approach in more than half (52.2%) of these patients, either because iCT demonstrated unexpected residual tumor masses or because the second scan revealed additional tumor tissue that was not detected in the first scan due to overlay by osseous tumor parts; in these cases resection was continued. In the remaining cases resection was concluded as planned because iCT verified the surgeon's microscopic estimation of tumor resection status. Postoperative visual outcome was favorable in more than 80% of patients. Intraoperative CT allows control of resection in case of uncertainty and can help to improve the extent of maximal safe resection, especially in case of osseous tumor parts and masses within the [[orbit]] ((Terpolilli NA, Rachinger W, Kunz M, Thon N, Flatz WH, Tonn JC, Schichor C. Orbit-associated tumors: navigation and control of resection using intraoperative computed tomography. J Neurosurg. 2015 Nov 13:1-9. [Epub ahead of print] PubMed PMID: 26566206. )). The benefits of [[Intraoperative magnetic resonance imaging]] (iMRI) in complex meningioma surgery are doubtful; however, it may still prove to be effective in certain subsets of complex meningiomas ((Soleman J, Fathi AR, Marbacher S, Fandino J. The role of intraoperative magnetic resonance imaging in complex meningioma surgery. Magn Reson Imaging. 2013 Jul;31(6):923-9. doi: 10.1016/j.mri.2012.12.005. Epub 2013 Feb 28. PubMed PMID: 23453762. )). ---- [[Atlas fracture]] and [[axis fracture]] are complex and surgical management may be difficult and challenging due to the anatomical relationship between the [[vertebra]] and neurovascular structures. The use of a [[navigation]] system based on an [[intraoperative computed tomography]] allows a real-time visualization of the [[vertebra]]e, reducing the risks of [[screw misplacement]] and consequent [[complication]]s ((Costa F, Ortolina A, Attuati L, Cardia A, Tomei M, Riva M, Balzarini L, Fornari M. Management of C1-2 traumatic fractures using an intraoperative 3D imaging-based navigation system. J Neurosurg Spine. 2015 Feb;22(2):128-33. doi: 10.3171/2014.10.SPINE14122. Epub 2014 Nov 21. PubMed PMID: 25415483. )). ===== Case series ===== A study refers to a consecutive series of patients undergoing either single-room iCT (January 2014-August 2014) or dual-room iCT (DR-iCT) (September 2014-July 2016). A further group undergoing surgery without iCT in the interconnected operating rooms represents the reference group. Workflow measurements and infection rates were calculated. Indications for iCT and utilization rates were compared for each of the devices. CT image quality was rated. Application of DR-iCT led to a broader use of this technique as compared to the single-room device, which concerned in particular stereotactic neurosurgery. Accordingly, iCT utilization rates significantly increased (up to 50.8 ± 4.6 surgeries per month, p < 0.001). Workflow was slightly prolonged in case of DR-iCT imaging; the difference, however, was not statistically significant. Infections rates were low (range 0.0-0.17 infections per month) and not influenced by the utilization rate. Image quality of the DR-iCT was classified as very good in 34/43 evaluated microsurgical patients. The use of DR-iCT enhances utilization rates with a broader field of indications for intraoperative imaging. Workflow measurements are not significantly prolonged. The technology is safe, and the imaging quality of modern devices can be expected to be good ((Lenski M, Hofereiter J, Terpolilli N, Sandner T, Zausinger S, Tonn JC, Kreth FW, Schichor C. Dual-room CT with a sliding gantry for intraoperative imaging: feasibility and workflow analysis of an interdisciplinary concept. Int J Comput Assist Radiol Surg. 2018 Jun 22. doi: 10.1007/s11548-018-1812-9. [Epub ahead of print] PubMed PMID: 29934791. )). ===== Airo Mobile Intraoperative CT ===== [[Airo Mobile Intraoperative CT]] intraoperative_computed_tomography.txt Last modified: 2024/06/07 02:57by 127.0.0.1